GTBANK Azikiwe Rd, Port-Harcourt, Rivers state.

 

 

 

Client: GT BANK 

Project Duration:

12 August 2015 to 22 August 2015

Narration:

Engineering Safety Investigation conducted on the Three (3) level bank building, sequel to the repeated observation of vibrations of the bank building.

Report of the investigation concluded that;

  • The vibrations observed in the building resulted from some heavy-duty construction work taking place within close proximity to the bank,
  • The overall building structure exhibited no signs of distress (indeed it satisfactorily bridled the “tremors”), and is hereby certified structurally intact from the results of the tests,
  • The hairline cracks observed on the building envelope can be treated by grinding & filling with epoxy material, this is then screeded with putty & painted over neatly,

Columns should be introduced at the three points on the rear fence with long diagonal cracks to limit their propagation.